TorsioEngineering

ISO fits and tolerances calculator

Pick a diameter and a fit (H7/g6, H7/k6, H7/p6 or any ISO combination) and get the hole and shaft deviations, the limits of size, the maximum and minimum clearance and whether it is a clearance, transition or interference fit. Or start from the clearance you want and find the fit.

Free, no sign-up, runs in your browser: your data never leaves your computer.

What it calculates

Method

The hole and the shaft each have a tolerance zone: its width is the standard tolerance IT of the grade, its position is the fundamental deviation of the letter for the diameter range. The clearance is the hole size minus the shaft size: its maximum and minimum follow from the deviations.

Worked example

Example: a hub on a 30 mm shaft with an H7/k6 fit (light press fit, with a key).
Diameter rangeover 18 up to 30 mm
Hole H7+21 / 0 µm → 30.000 … 30.021 mm
Shaft k6+15 / +2 µm → 30.002 … 30.015 mm
Maximum clearance+19 µm (largest hole, smallest shaft)
Maximum interference15 µm (smallest hole, largest shaft)
Type of fittransition: it can come out loose or tight

The ISO 286 tables in the calculator are checked by 904 tests: about 50 published deviations, the Δ rule on every range and the growth of IT with grade.

ISO fit tables

Common fits at 30 mm

Hole-basis fits on a 30 mm diameter, in µm (negative clearance = interference). Computed by Torsio.

FitMax clearanceMin clearanceType
H11/c11+370+110clearance
H9/d9+169+65clearance
H8/f7+74+20clearance
H7/f7+62+20clearance
H7/g6+41+7clearance
H7/h6+340clearance
H8/h7+540clearance
H7/js6+27.5−6.5transition
H7/k6+19−15transition
H7/n6+6−28transition
H7/p6−1−35interference
H7/r6−7−41interference
H7/s6−14−48interference

Deviations by diameter range

Upper / lower deviation in µm, ISO 286-2, for the most used tolerance classes. Holes in capitals, shafts in lower case.

Size [mm]H7H8f7g6h6js6k6n6p6
up to 3+10 / 0+14 / 0−6 / −16−2 / −80 / −6±3+6 / 0+10 / +4+12 / +6
over 3 up to 6+12 / 0+18 / 0−10 / −22−4 / −120 / −8±4+9 / +1+16 / +8+20 / +12
over 6 up to 10+15 / 0+22 / 0−13 / −28−5 / −140 / −9±4.5+10 / +1+19 / +10+24 / +15
over 10 up to 18+18 / 0+27 / 0−16 / −34−6 / −170 / −11±5.5+12 / +1+23 / +12+29 / +18
over 18 up to 30+21 / 0+33 / 0−20 / −41−7 / −200 / −13±6.5+15 / +2+28 / +15+35 / +22
over 30 up to 50+25 / 0+39 / 0−25 / −50−9 / −250 / −16±8+18 / +2+33 / +17+42 / +26
over 50 up to 80+30 / 0+46 / 0−30 / −60−10 / −290 / −19±9.5+21 / +2+39 / +20+51 / +32
over 80 up to 120+35 / 0+54 / 0−36 / −71−12 / −340 / −22±11+25 / +3+45 / +23+59 / +37
over 120 up to 180+40 / 0+63 / 0−43 / −83−14 / −390 / −25±12.5+28 / +3+52 / +27+68 / +43
over 180 up to 250+46 / 0+72 / 0−50 / −96−15 / −440 / −29±14.5+33 / +4+60 / +31+79 / +50
over 250 up to 315+52 / 0+81 / 0−56 / −108−17 / −490 / −32±16+36 / +4+66 / +34+88 / +56
over 315 up to 400+57 / 0+89 / 0−62 / −119−18 / −540 / −36±18+40 / +4+73 / +37+98 / +62
over 400 up to 500+63 / 0+97 / 0−68 / −131−20 / −600 / −40±20+45 / +5+80 / +40+108 / +68

Full table of each fit, 1 to 500 mm

Hole basis: H11/c11 · H9/d9 · H8/f7 · H7/f7 · H7/g6 · H7/h6 · H8/h7 · H7/js6 · H7/k6 · H7/n6 · H7/p6 · H7/r6 · H7/s6

Shaft basis: C11/h11 · D9/h9 · F8/h7 · G7/h6 · K7/h6 · N7/h6 · P7/h6 · S7/h6

For any other size, letter or grade (IT5–IT11, holes C–S, shafts c–s, up to 500 mm) open the calculator: it also gives the drawing callout and works backwards from the clearance you want.

What you get

Limits and next step

Letters a, b, j and t…zc and the isolated exceptions of the standard are not handled. The pressure and the transmissible torque of an interference fit (Lamé) are calculated in the shrink fit station D-07, where the fit can be passed with one click.

Questions

How do I read H7/g6?
The capital letter and number are the hole, the lower case ones the shaft. The letter sets the position of the tolerance zone (H: lower deviation zero, g: a little below the nominal size), the number is the IT grade, i.e. the width of the zone.
Hole basis or shaft basis?
Hole basis (H…) is the usual choice because holes are made with fixed-size tools (reamers, gauges); shaft basis (…h) is used when one drawn shaft carries several parts with different fits.
Which fit for a bearing, a gear hub, a sliding pin?
As a first orientation: sliding pins and guides H7/g6 or H7/h6, hubs with a key H7/k6, press fits H7/p6 to H7/s6. For rolling bearings follow the bearing manufacturer's tables, because the bearing bore has its own tolerance.
Can it calculate the force or pressure of a press fit?
Not in this station: the interference fit can be passed to the shrink fit station D-07, which gives the contact pressure, the transmissible torque and the stresses.
Is it free?
Yes, free and without sign-up. Everything runs in your browser.