Pick a diameter and a fit (H7/g6, H7/k6, H7/p6 or any ISO combination) and get the hole and shaft deviations, the limits of size, the maximum and minimum clearance and whether it is a clearance, transition or interference fit. Or start from the clearance you want and find the fit.
Free, no sign-up, runs in your browser: your data never leaves your computer.
The hole and the shaft each have a tolerance zone: its width is the standard tolerance IT of the grade, its position is the fundamental deviation of the letter for the diameter range. The clearance is the hole size minus the shaft size: its maximum and minimum follow from the deviations.
| Diameter range | over 18 up to 30 mm |
|---|---|
| Hole H7 | +21 / 0 µm → 30.000 … 30.021 mm |
| Shaft k6 | +15 / +2 µm → 30.002 … 30.015 mm |
| Maximum clearance | +19 µm (largest hole, smallest shaft) |
| Maximum interference | 15 µm (smallest hole, largest shaft) |
| Type of fit | transition: it can come out loose or tight |
The ISO 286 tables in the calculator are checked by 904 tests: about 50 published deviations, the Δ rule on every range and the growth of IT with grade.
Hole-basis fits on a 30 mm diameter, in µm (negative clearance = interference). Computed by Torsio.
| Fit | Max clearance | Min clearance | Type |
|---|---|---|---|
| H11/c11 | +370 | +110 | clearance |
| H9/d9 | +169 | +65 | clearance |
| H8/f7 | +74 | +20 | clearance |
| H7/f7 | +62 | +20 | clearance |
| H7/g6 | +41 | +7 | clearance |
| H7/h6 | +34 | 0 | clearance |
| H8/h7 | +54 | 0 | clearance |
| H7/js6 | +27.5 | −6.5 | transition |
| H7/k6 | +19 | −15 | transition |
| H7/n6 | +6 | −28 | transition |
| H7/p6 | −1 | −35 | interference |
| H7/r6 | −7 | −41 | interference |
| H7/s6 | −14 | −48 | interference |
Upper / lower deviation in µm, ISO 286-2, for the most used tolerance classes. Holes in capitals, shafts in lower case.
| Size [mm] | H7 | H8 | f7 | g6 | h6 | js6 | k6 | n6 | p6 |
|---|---|---|---|---|---|---|---|---|---|
| up to 3 | +10 / 0 | +14 / 0 | −6 / −16 | −2 / −8 | 0 / −6 | ±3 | +6 / 0 | +10 / +4 | +12 / +6 |
| over 3 up to 6 | +12 / 0 | +18 / 0 | −10 / −22 | −4 / −12 | 0 / −8 | ±4 | +9 / +1 | +16 / +8 | +20 / +12 |
| over 6 up to 10 | +15 / 0 | +22 / 0 | −13 / −28 | −5 / −14 | 0 / −9 | ±4.5 | +10 / +1 | +19 / +10 | +24 / +15 |
| over 10 up to 18 | +18 / 0 | +27 / 0 | −16 / −34 | −6 / −17 | 0 / −11 | ±5.5 | +12 / +1 | +23 / +12 | +29 / +18 |
| over 18 up to 30 | +21 / 0 | +33 / 0 | −20 / −41 | −7 / −20 | 0 / −13 | ±6.5 | +15 / +2 | +28 / +15 | +35 / +22 |
| over 30 up to 50 | +25 / 0 | +39 / 0 | −25 / −50 | −9 / −25 | 0 / −16 | ±8 | +18 / +2 | +33 / +17 | +42 / +26 |
| over 50 up to 80 | +30 / 0 | +46 / 0 | −30 / −60 | −10 / −29 | 0 / −19 | ±9.5 | +21 / +2 | +39 / +20 | +51 / +32 |
| over 80 up to 120 | +35 / 0 | +54 / 0 | −36 / −71 | −12 / −34 | 0 / −22 | ±11 | +25 / +3 | +45 / +23 | +59 / +37 |
| over 120 up to 180 | +40 / 0 | +63 / 0 | −43 / −83 | −14 / −39 | 0 / −25 | ±12.5 | +28 / +3 | +52 / +27 | +68 / +43 |
| over 180 up to 250 | +46 / 0 | +72 / 0 | −50 / −96 | −15 / −44 | 0 / −29 | ±14.5 | +33 / +4 | +60 / +31 | +79 / +50 |
| over 250 up to 315 | +52 / 0 | +81 / 0 | −56 / −108 | −17 / −49 | 0 / −32 | ±16 | +36 / +4 | +66 / +34 | +88 / +56 |
| over 315 up to 400 | +57 / 0 | +89 / 0 | −62 / −119 | −18 / −54 | 0 / −36 | ±18 | +40 / +4 | +73 / +37 | +98 / +62 |
| over 400 up to 500 | +63 / 0 | +97 / 0 | −68 / −131 | −20 / −60 | 0 / −40 | ±20 | +45 / +5 | +80 / +40 | +108 / +68 |
Hole basis: H11/c11 · H9/d9 · H8/f7 · H7/f7 · H7/g6 · H7/h6 · H8/h7 · H7/js6 · H7/k6 · H7/n6 · H7/p6 · H7/r6 · H7/s6
Shaft basis: C11/h11 · D9/h9 · F8/h7 · G7/h6 · K7/h6 · N7/h6 · P7/h6 · S7/h6
For any other size, letter or grade (IT5–IT11, holes C–S, shafts c–s, up to 500 mm) open the calculator: it also gives the drawing callout and works backwards from the clearance you want.
Letters a, b, j and t…zc and the isolated exceptions of the standard are not handled. The pressure and the transmissible torque of an interference fit (Lamé) are calculated in the shrink fit station D-07, where the fit can be passed with one click.