TorsioEngineering

Torsio › ISO fits › S7/h6

S7/h6 fit

Heavy interference, shaft basis. ISO 286 interference fit, shaft basis. Below: hole and shaft deviations, limits of size and clearance for every diameter range up to 500 mm.

Free, no sign-up, runs in your browser: your data never leaves your computer.

Example on 30 mm

Hole S7−27 / −48 µm → 29.952 … 29.973 mm
Shaft h60 / −13 µm → 29.987 … 30.000 mm
Largest hole, smallest shaft14 µm interference
Smallest hole, largest shaft48 µm interference
Typeinterference

ISO 286 table of S7/h6

ISO 286-2 deviations and clearances of S7/h6 in µm (negative clearance = interference). Computed by Torsio.

Size [mm]Hole S7 [µm]Shaft h6 [µm]Max clearanceMin clearanceType
up to 3−14 / −240 / −6−8−24interference
over 3 up to 6−15 / −270 / −8−7−27interference
over 6 up to 10−17 / −320 / −9−8−32interference
over 10 up to 18−21 / −390 / −11−10−39interference
over 18 up to 30−27 / −480 / −13−14−48interference
over 30 up to 40−34 / −590 / −16−18−59interference
over 40 up to 50−34 / −590 / −16−18−59interference
over 50 up to 65−42 / −720 / −19−23−72interference
over 65 up to 80−48 / −780 / −19−29−78interference
over 80 up to 100−58 / −930 / −22−36−93interference
over 100 up to 120−66 / −1010 / −22−44−101interference
over 120 up to 140−77 / −1170 / −25−52−117interference
over 140 up to 160−85 / −1250 / −25−60−125interference
over 160 up to 180−93 / −1330 / −25−68−133interference
over 180 up to 200−105 / −1510 / −29−76−151interference
over 200 up to 225−113 / −1590 / −29−84−159interference
over 225 up to 250−123 / −1690 / −29−94−169interference
over 250 up to 280−138 / −1900 / −32−106−190interference
over 280 up to 315−150 / −2020 / −32−118−202interference
over 315 up to 355−169 / −2260 / −36−133−226interference
over 355 up to 400−187 / −2440 / −36−151−244interference
over 400 up to 450−209 / −2720 / −40−169−272interference
over 450 up to 500−229 / −2920 / −40−189−292interference

For any other diameter, or to compare fits and work back from the clearance you want, open the calculator: it also gives the drawing callout and the calculation report.

When to use it

Heavy interference, shaft basis.

It is an interference fit: on every size the shaft is larger than the hole, so the parts are pressed or shrunk together and the fit itself can carry torque.

Indicative roughness: hole Ra 0.8-1.6 µm, shaft Ra 0.4-0.8 µm.

On the drawing: Ø30 S7/h6 on the assembly, Ø30 S7 on the hub and Ø30 h6 on the shaft (or the limits of size).

Questions

Is S7/h6 a clearance or an interference fit?
Interference. It is an interference fit: on every size the shaft is larger than the hole, so the parts are pressed or shrunk together and the fit itself can carry torque.
What clearance does S7/h6 give on 50 mm?
From −59 to −18 µm (range over 40 up to 50 mm; negative values are interference).
And on 100 mm?
From −93 to −36 µm (range over 80 up to 100 mm).
Where do these values come from?
From the ISO 286-1 and 286-2 tables built into the Torsio calculator, checked by 904 tests against published deviations. For a contract drawing always refer to the standard.

Other shaft basis fits

Hole basis fits → · All ISO fit tables and the calculator →