TorsioEngineering

Torsio › ISO fits › F8/h7

F8/h7 fit

Close running, shaft basis. ISO 286 clearance fit, shaft basis. Below: hole and shaft deviations, limits of size and clearance for every diameter range up to 500 mm.

Free, no sign-up, runs in your browser: your data never leaves your computer.

Example on 30 mm

Hole F8+53 / +20 µm → 30.020 … 30.053 mm
Shaft h70 / −21 µm → 29.979 … 30.000 mm
Largest hole, smallest shaft74 µm clearance
Smallest hole, largest shaft20 µm clearance
Typeclearance

ISO 286 table of F8/h7

ISO 286-2 deviations and clearances of F8/h7 in µm (negative clearance = interference). Computed by Torsio.

Size [mm]Hole F8 [µm]Shaft h7 [µm]Max clearanceMin clearanceType
up to 3+20 / +60 / −10+30+6clearance
over 3 up to 6+28 / +100 / −12+40+10clearance
over 6 up to 10+35 / +130 / −15+50+13clearance
over 10 up to 18+43 / +160 / −18+61+16clearance
over 18 up to 30+53 / +200 / −21+74+20clearance
over 30 up to 50+64 / +250 / −25+89+25clearance
over 50 up to 80+76 / +300 / −30+106+30clearance
over 80 up to 120+90 / +360 / −35+125+36clearance
over 120 up to 180+106 / +430 / −40+146+43clearance
over 180 up to 250+122 / +500 / −46+168+50clearance
over 250 up to 315+137 / +560 / −52+189+56clearance
over 315 up to 400+151 / +620 / −57+208+62clearance
over 400 up to 500+165 / +680 / −63+228+68clearance

For any other diameter, or to compare fits and work back from the clearance you want, open the calculator: it also gives the drawing callout and the calculation report.

When to use it

Close running, shaft basis.

It is a clearance fit: on every size the hole is larger than the shaft, so the parts slide or turn.

Indicative roughness: hole Ra 1.6 µm, shaft Ra 0.8-1.6 µm.

On the drawing: Ø30 F8/h7 on the assembly, Ø30 F8 on the hub and Ø30 h7 on the shaft (or the limits of size).

Questions

Is F8/h7 a clearance or an interference fit?
Clearance. It is a clearance fit: on every size the hole is larger than the shaft, so the parts slide or turn.
What clearance does F8/h7 give on 50 mm?
From +25 to +89 µm (range over 30 up to 50 mm; negative values are interference).
And on 100 mm?
From +36 to +125 µm (range over 80 up to 120 mm).
Where do these values come from?
From the ISO 286-1 and 286-2 tables built into the Torsio calculator, checked by 904 tests against published deviations. For a contract drawing always refer to the standard.

Other shaft basis fits

Hole basis fits → · All ISO fit tables and the calculator →