TorsioEngineering

Torsio › ISO fits › H7/s6

H7/s6 fit

Heavy interference, shrink fit. ISO 286 interference fit, hole basis. Below: hole and shaft deviations, limits of size and clearance for every diameter range up to 500 mm.

Free, no sign-up, runs in your browser: your data never leaves your computer.

Example on 30 mm

Hole H7+21 / 0 µm → 30.000 … 30.021 mm
Shaft s6+48 / +35 µm → 30.035 … 30.048 mm
Largest hole, smallest shaft14 µm interference
Smallest hole, largest shaft48 µm interference
Typeinterference

ISO 286 table of H7/s6

ISO 286-2 deviations and clearances of H7/s6 in µm (negative clearance = interference). Computed by Torsio.

Size [mm]Hole H7 [µm]Shaft s6 [µm]Max clearanceMin clearanceType
up to 3+10 / 0+20 / +14−4−20interference
over 3 up to 6+12 / 0+27 / +19−7−27interference
over 6 up to 10+15 / 0+32 / +23−8−32interference
over 10 up to 18+18 / 0+39 / +28−10−39interference
over 18 up to 30+21 / 0+48 / +35−14−48interference
over 30 up to 40+25 / 0+59 / +43−18−59interference
over 40 up to 50+25 / 0+59 / +43−18−59interference
over 50 up to 65+30 / 0+72 / +53−23−72interference
over 65 up to 80+30 / 0+78 / +59−29−78interference
over 80 up to 100+35 / 0+93 / +71−36−93interference
over 100 up to 120+35 / 0+101 / +79−44−101interference
over 120 up to 140+40 / 0+117 / +92−52−117interference
over 140 up to 160+40 / 0+125 / +100−60−125interference
over 160 up to 180+40 / 0+133 / +108−68−133interference
over 180 up to 200+46 / 0+151 / +122−76−151interference
over 200 up to 225+46 / 0+159 / +130−84−159interference
over 225 up to 250+46 / 0+169 / +140−94−169interference
over 250 up to 280+52 / 0+190 / +158−106−190interference
over 280 up to 315+52 / 0+202 / +170−118−202interference
over 315 up to 355+57 / 0+226 / +190−133−226interference
over 355 up to 400+57 / 0+244 / +208−151−244interference
over 400 up to 450+63 / 0+272 / +232−169−272interference
over 450 up to 500+63 / 0+292 / +252−189−292interference

For any other diameter, or to compare fits and work back from the clearance you want, open the calculator: it also gives the drawing callout and the calculation report.

When to use it

Heavy interference, shrink fit.

It is an interference fit: on every size the shaft is larger than the hole, so the parts are pressed or shrunk together and the fit itself can carry torque.

Indicative roughness: hole Ra 0.8-1.6 µm, shaft Ra 0.4-0.8 µm.

On the drawing: Ø30 H7/s6 on the assembly, Ø30 H7 on the hub and Ø30 s6 on the shaft (or the limits of size).

Questions

Is H7/s6 a clearance or an interference fit?
Interference. It is an interference fit: on every size the shaft is larger than the hole, so the parts are pressed or shrunk together and the fit itself can carry torque.
What clearance does H7/s6 give on 50 mm?
From −59 to −18 µm (range over 40 up to 50 mm; negative values are interference).
And on 100 mm?
From −93 to −36 µm (range over 80 up to 100 mm).
Where do these values come from?
From the ISO 286-1 and 286-2 tables built into the Torsio calculator, checked by 904 tests against published deviations. For a contract drawing always refer to the standard.

Other hole basis fits

Shaft basis fits → · All ISO fit tables and the calculator →