How many bolts, which size, how much preload and which tightening torque: friction joints and flange couplings, external axial loads with the joint diagram, and power screws, with the calculation report.
Free, no sign-up, runs in your browser: your data never leaves your computer.
The friction joint transmits the load through the friction between the plates: the preload comes from the required safety factor, the bolt size from the allowable stress on the resisting area, and the tightening torque from the thread geometry with the friction under the head.
| Torque | Mt = 32 kN·m on a bolt circle of 210 mm |
|---|---|
| Friction | f = 0.14 between the flanges and in the thread, 1 friction surface |
| Safety factor and class | X = 1.5, class 12.9 |
| Bolt size | M30 (Ares = 452 mm²); at most 14 fit on the circle |
| Number of bolts | 10 × M30 12.9 |
| Preload per bolt | 326.5 kN |
| Tightening torque | 1769 N·m per bolt |
| Bolt safety factor | 1.50: 10.02 bolts are needed, rounded down to 10 because the factor drops by less than 0.5 %, as in the hand solution |
The calculator reproduces 30 checks from hand-solved exercises: flanges, a pressure vessel cover, a vise screw.
Preliminary sizing: bolt fatigue and thermal effects are not included. For the final design use VDI 2230 and the friction values of your bolts.