TorsioEngineering

Torsio › ISO fits › H7/js6

H7/js6 fit

Transition, mallet assembly. ISO 286 transition fit, hole basis. Below: hole and shaft deviations, limits of size and clearance for every diameter range up to 500 mm.

Free, no sign-up, runs in your browser: your data never leaves your computer.

Example on 30 mm

Hole H7+21 / 0 µm → 30.000 … 30.021 mm
Shaft js6+6.5 / −6.5 µm → 29.994 … 30.006 mm
Largest hole, smallest shaft27.5 µm clearance
Smallest hole, largest shaft6.5 µm interference
Typetransition

ISO 286 table of H7/js6

ISO 286-2 deviations and clearances of H7/js6 in µm (negative clearance = interference). Computed by Torsio.

Size [mm]Hole H7 [µm]Shaft js6 [µm]Max clearanceMin clearanceType
up to 3+10 / 0+3 / −3+13−3transition
over 3 up to 6+12 / 0+4 / −4+16−4transition
over 6 up to 10+15 / 0+4.5 / −4.5+19.5−4.5transition
over 10 up to 18+18 / 0+5.5 / −5.5+23.5−5.5transition
over 18 up to 30+21 / 0+6.5 / −6.5+27.5−6.5transition
over 30 up to 40+25 / 0+8 / −8+33−8transition
over 40 up to 50+25 / 0+8 / −8+33−8transition
over 50 up to 65+30 / 0+9.5 / −9.5+39.5−9.5transition
over 65 up to 80+30 / 0+9.5 / −9.5+39.5−9.5transition
over 80 up to 100+35 / 0+11 / −11+46−11transition
over 100 up to 120+35 / 0+11 / −11+46−11transition
over 120 up to 140+40 / 0+12.5 / −12.5+52.5−12.5transition
over 140 up to 160+40 / 0+12.5 / −12.5+52.5−12.5transition
over 160 up to 180+40 / 0+12.5 / −12.5+52.5−12.5transition
over 180 up to 200+46 / 0+14.5 / −14.5+60.5−14.5transition
over 200 up to 225+46 / 0+14.5 / −14.5+60.5−14.5transition
over 225 up to 250+46 / 0+14.5 / −14.5+60.5−14.5transition
over 250 up to 280+52 / 0+16 / −16+68−16transition
over 280 up to 315+52 / 0+16 / −16+68−16transition
over 315 up to 355+57 / 0+18 / −18+75−18transition
over 355 up to 400+57 / 0+18 / −18+75−18transition
over 400 up to 450+63 / 0+20 / −20+83−20transition
over 450 up to 500+63 / 0+20 / −20+83−20transition

For any other diameter, or to compare fits and work back from the clearance you want, open the calculator: it also gives the drawing callout and the calculation report.

When to use it

Transition, mallet assembly.

It is a transition fit: depending on the actual sizes it can come out with a little clearance or a little interference. It locates the parts accurately; a key or a pin carries the torque.

Indicative roughness: hole Ra 1.6 µm, shaft Ra 0.8 µm. Typical machining: shaft by cylindrical grinding, hole by fine reaming or boring.

On the drawing: Ø30 H7/js6 on the assembly, Ø30 H7 on the hub and Ø30 js6 on the shaft (or the limits of size).

Questions

Is H7/js6 a clearance or an interference fit?
Transition. It is a transition fit: depending on the actual sizes it can come out with a little clearance or a little interference. It locates the parts accurately; a key or a pin carries the torque.
What clearance does H7/js6 give on 50 mm?
From −8 to +33 µm (range over 40 up to 50 mm; negative values are interference).
And on 100 mm?
From −11 to +46 µm (range over 80 up to 100 mm).
Where do these values come from?
From the ISO 286-1 and 286-2 tables built into the Torsio calculator, checked by 904 tests against published deviations. For a contract drawing always refer to the standard.

Other hole basis fits

Shaft basis fits → · All ISO fit tables and the calculator →